5.2 Error Diagnosis and Troubleshooting

— 5-9 —

Status when Alarm Occurred

E

At power ON

Parameter

Cn-01 bit 0 = 0

When servo ON (/S-ON)

signal turned ON

A

,

B

, C, D, E

On speed reference input

A

,

B

, C, D, E

A

,

B

, C, D, E

1 to 3 seconds after

power ON

Parameter

Cn-01 bit 0 = 1

Cause

Remedy

A

Servomotor wiring incorrect or

disconnected.

Check wiring and connectors at

Servomotor.

B

Encoder wiring incorrect or disconnected.

Check wiring and connectors at encoder.

C

Incremental encoder power not supplied

from Servopack.

Use the Servopack power supply for the

encoder.

D

Encoder defective.

Replace Servomotor.

E

Circuit board (1PWB) defective.

Replace Servopack.

10.A.C2

Display and Outputs

Digital Operator Display

Alarm Name

Alarm Output

A.C2

Encoder phase detection error

Output transistor is OFF

(alarm state)

Status when Alarm Occurred

D

At power ON

During Servomotor

operation

A

,

B

,

C

, D

1 to 3 seconds after

power ON

A

,

B

,

C

, D

Cause

Remedy

A

Noise in encoder wiring.

Separate encoder wiring from main wiring

circuits.

B

Encoder wiring incorrect or poor

connection.

Check wiring and connectors at encoder.

C

Encoder defective.

Replace Servomotor.

D

Circuit board (1PWB) defective.

Replace Servopack.