Yaskawa Sigma Mini User Manual

Page 33

Advertising
background image

BASIC OPERATION

1.3.3 Examples of Connecting Host Controllerscont.

— 1-20 —

Example of Connecting to OMRON C500-NC112 Position Control Unit

Servopack for Position Control

+12V

+

+24V

1A
1B

2A

2B

3A

3B

4A

4B

5A

5B
8A
8B
9A
9B
10A
10B
7A
7B

+24V

CN2

CN1

CN1

+24VIN

/S-ON

PCO
SG
ALM

SG-COM

PULS
/PULS
SIGN
/SIGN

CLR
/CLR

9

1

10

13

7

3

14
15
16
17
18
19

+24V

1Ry

*1

1Ry

0

24

V

C500-NC112

(Made by OMRON)

Servomotor

Servopack

I/O power supply

CW LIMIT

CCW LIMIT

EMERGENCY

STOP
EXTERNAL

INTERRUPT

ORIGIN

ORIGIN

PROXIMITY

LOCAL

READY

+5V
+5V

PULSE OUTPUT

CW+CCW

DIRECTION
OUTPUT

CW

External

power supply

+5V

+5V

*1 The ALM signal is output for approximately two seconds when the power is turned ON. Consider this when

designing the power ON sequence.

Use the ALM signal to operate the alarm detection relay (Relay 1Ry) and turn OFF the power supply to the

Servopack.

Note Only signals for the OMRON C500-NC112 Position Control Unit and the Yaskawa Servopack are

shown here.

DC24V
GND

U

V

W

M

PG

1

Positions

Advertising