Yaskawa Sigma-5 User Manual: Design and Maintenance - Linear Motors User Manual
Page 106

4 Operation
4.2.5 Encoder Output Pulse
4-16
Note: A SERVOPACK with software version 0023 or later supports this parameter.
Parameter
Meaning
When Enabled
Classification
Pn081
n.0
[Factory Setting]
Outputs phase-C pulse only in forward direction.
After restart
Setup
n.1
Outputs phase-C pulse in forward and reverse
direction.
• Setting of Pn081.0
Do not change the factory setting if the zero point position of the existing equipment
must remain as is.
• When Pn081.0=1, the width of the phase-C pulse output is narrower than that of
the phase-A pulse in some cases.
• As shown in the following figure, there is a one-eighth scale pitch difference in posi-
tions between the two settings (Pn081.0=1 and Pn081.0=0) for the phase-C pulse
output, the zero point return command, and the phase-C detection by phase-C
latch function.
1/8
scale pitch
Pn081.0 =
0
Zero point
Zero point
Moves to forward
1 scale pitch
Pn081.0 =
1