5 using the servopack with a dc power input, Warning, 1) parameter settings – Yaskawa Sigma-5 User Manual: Design and Maintenance - Linear Motors User Manual

Page 61

Advertising
background image

3.1 Main Circuit Wiring

3-15

3

Wiring and Connection

3.1.5 Using the SERVOPACK with a DC Power Input

(1) Parameter Settings

When using the SERVOPACK with a DC power input, set parameter Pn001.2 to 1.

Observe the following precautions when using a DC power input.

(2) DC Power Supply Input Terminals for the Main and Control Circuits

„

Three-phase, 200-V SGDV-†††A

(††† = R70, R90, 1R6, 2R8, 3R8, 5R5, 7R6, 120, 180, 200, 330)

„

Three-phase, 200-V SGDV-†††A (††† = 550)

„

Three-phase, 400-V SGDV-†††D

(††† = 1R9, 3R5, 5R4, 8R4, 120, 170, 260)

Parameter

Meaning

When Enabled Classification

Pn001

n.†0††

Enables use of AC power input.

After restart

Setup

n.†1††

Enables use of DC power input.

WARNING

• Either AC or DC power can be input to the 200 V, 400 V SERVOPACKs. Always set Pn001.2 to 1 to spec-

ify a DC power input before inputting DC power. Only AC power can be input to the 100 V SERVOPACKs.
If DC power is input without changing the parameter setting, the SERVOPACK’s internal elements will burn and

may cause fire or equipment damage.

• With a DC power input, time is required to discharge electricity after the main power supply is turned OFF.

A high residual voltage may remain in the SERVOPACK after the power supply is turned OFF. Be careful

not to get an electric shock.

• Install fuses on the wires if DC power is used.
• Linear servomotor returns a regenerated energy to the power supply. The SERVOPACK that can use a

DC power supply is not capable of processing the regenerated energy. Provide measures to process the

regenerated energy on the power supply.

• With a DC power input, connect an external inrush current limit circuit.

Failure to observe this caution may result in damage to the product.

Terminal Symbols

Name

Specification

B1/

Main circuit plus terminal

270 to 320 VDC

2

Main circuit minus terminal

0 VDC

L1C, L2C

Control power supply input terminal

200 to 230 VAC

Terminal Symbols

Name

Specification

B1/

Main circuit plus terminal

270 to 320 VDC

Main circuit minus terminal

0 VDC

L1C, L2C

Control power supply input terminal

200 to 230 VAC

Terminal Symbols

Name

Specification

B1/

Main circuit plus terminal

513 to 648 VDC

2

Main circuit minus terminal

0 VDC

24 V, 0 V

Control power supply input terminal

24 VDC (

±15%)

Advertising