6 linear scale connection, 1 linear scale signal (cn2) names and functions, 2 serial converter unit – Yaskawa Sigma-5 User Manual: Design and Maintenance - Linear Motors User Manual

Page 76: 1) model: jzdp-d00†-†††-e

Advertising
background image

3 Wiring and Connection

3.6.1 Linear Scale Signal (CN2) Names and Functions

3-30

3.6 Linear Scale Connection

This section describes the linear scale signal (CN2) names, functions, and connection examples.

3.6.1 Linear Scale Signal (CN2) Names and Functions

The following table shows the names and functions of linear scale signals (CN2).

∗ Do not use pins 3 and 4.

3.6.2 Serial Converter Unit

(1) Model: JZDP-D00†-†††-E

The following table shows the characteristics and specifications of the serial converter unit.

∗ Input a value within the specified range. Otherwise, incorrect position information is output, and the device may be

damaged.

Signal Name

Pin No.

Function

PG 5 V

1

Linear scale power supply +5 V

PG 0 V

2

Linear scale power supply 0 V

3

*

4

*

PS

5

Serial data (+)

/PS

6

Serial data (-)

Shield

Shell

Items

JZDP-D00…-………-E

JZDP-G00…-………-E

Electrical

Characteristics

Power Supply Voltage

+5.0 V

±5%, ripple content 5% max.

Current Consumption

120 mA Typ. 350 mA max.

Signal Resolution

1/256 pitch of input 2-phase sine
wave

1/4096 pitch of input 2-phase
sine wave pitch

Max. Response Frequency

250 kHz

100 kHz

Analog Input Signals

(cos, sin, Ref)

Differential input amplitude: 0.4 V to 1.2 V
Input signal level: 1.5 V to 3.5 V

Hall Sensor Input Signal

CMOS level

Output Signal

Position data, hall sensor information, alarms

Output Method

Serial data communications

Output Circuit

Balanced type transceiver (SN75LBC176 or the equivalent), inter-
nal terminating resistor: 120

Ω

Mechanical

Characteristics

Approx. Mass

150 g

Vibration Resistance

98 m/s

2

max. (10 to 2500 Hz) in three directions

Shock Resistance

980 m/s

2

, (11 ms) two times in three directions

Environmental

Conditions

Surrounding Air Temperature 0

°C to 55°C

Storage Temperature

-20

°C to +80°C

Humidity

20% to 90%RH (without condensation)

Advertising