4.7 Safety Function
4-53
4
Operation
4.7.5 Connecting a Safety Device
There are two types of the safety function’s jumper connectors that are attached to SERVOPACKs. You must
remove the safety function’s jumper connector before connecting a safety function device. The connection
method depends on the connector type that is used. Read the following procedures well before you attach a
safety function device.
Use the following procedures to attach safety function devices.
(1) Connector Type A
1.
Remove the servomotor connection terminal connector while pressing the lock.
Applicable SERVOPACKs:
SGDV-R70F, -R90F, -2R1F, -R70A, -R90A, -1R6A, -2R8A, -1R9D, -3R5D, -5R4D
For SERVOPACK models not listed above, it is not necesassary to remove the servomotor connection ter-
mial connector. Go to step 2.
2.
Slide the lock injector on the safety function’s jumper connector to the SERVOPACK side to
unlock and remove the safety function’s jumper connector.
Note: The safety function’s jumper connector may be damaged if removed while the lock is still on.
Connector Type A
Connector Type B
Enlarged View
Servomotor
connection terminal connector
Lock
2. Remove the servomotor
connection terminal connector
while pressing the lock.
1. Press the lock.
Lock injector
Safety function’s
jumper connector
Enlarged View
Remove the safety function’s
jumper connector while the lock
injector is slid to the SERVOPACK
side.
2.
1. Slide the lock injector
to the SERVOPACK
side.