5 Adjustments

5.9.2 Using the Mode Switch (P/PI Switching)

5-64

„

Using the Position Error Pulse Level to Switch Modes

With this setting, the speed loop is switched to P control when the position error pulse exceeds the value set in
Pn10F.

This setting is effective with position control only.

<Example>
In this example, the mode switch is used to reduce the settling time. It is necessary to increase the speed loop
gain to reduce the settling time. Using the mode switch suppresses overshooting when speed loop gain is

increased.

Position
error pulse

Speed reference

Speed

Motor

speed

Time

P Control

PI Control

Pn10F

PI

Without Mode Switching

With Mode Switching

Motor
speed

Speed reference

Long settling time

Increase speed loop gain.

Settling time

Motor
speed

Overshoot

Overshoot

Motor
speed

Time

Motor
speed

Time

Time

Advertising