Yaskawa Sigma-5 User Manual: Design and Maintenance - Linear Motors User Manual
Page 208

5 Adjustments
5.9.2 Using the Mode Switch (P/PI Switching)
5-64
Using the Position Error Pulse Level to Switch Modes
With this setting, the speed loop is switched to P control when the position error pulse exceeds the value set in
Pn10F.
This setting is effective with position control only.
<Example>
In this example, the mode switch is used to reduce the settling time. It is necessary to increase the speed loop
gain to reduce the settling time. Using the mode switch suppresses overshooting when speed loop gain is
increased.
Position
error pulse
Speed reference
Speed
Motor
speed
Time
P Control
PI Control
Pn10F
PI
Without Mode Switching
With Mode Switching
Motor
speed
Speed reference
Long settling time
Increase speed loop gain.
Settling time
Motor
speed
Overshoot
Overshoot
Motor
speed
Time
Motor
speed
Time
Time