8.1 Troubleshooting

8-23

8

T

roubleshooting

A.F50:
Servomotor Main

Circuit Cable

Disconnection
(The servomotor did not

operate or power was not
supplied to the
servomotor even though
the servo ON command

was input when the
servomotor was ready to
receive it.)

A SERVOPACK fault occurred.

The SERVOPACK may be faulty.
Replace the SERVOPACK.

The wiring is not correct or there

is a faulty contact in the motor
wiring.

Check the wiring.

Make sure that the servomotor is
correctly wired.

CPF00:
Digital Operator

Transmission Error 1

The contact between the digital
operator and the SERVOPACK is
faulty.

Check the connector contact.

Insert securely the connector or
replace the cable.

Malfunction caused by noise
interference

Keep the digital operator or the
cable away from noise sources.

CPF01:
Digital Operator
Transmission Error 2

A digital operator fault occurred.

Disconnect the digital operator and

then re-connect it. If the alarm still
occurs, the digital operator may be
faulty. Replace the digital operator.

A SERVOPACK fault occurred.

Turn the power supply OFF and
then ON again. If the alarm still
occurs, the SERVOPACK may be
faulty. Replace the SERVOPACK.

Alarm:

Alarm Name

Cause

Investigative Actions

Corrective Actions