3 checking output force limiting during operation – Yaskawa Sigma-5 User Manual: Design and Maintenance - Linear Motors User Manual

Page 125

Advertising
background image

4.4 Limiting Force

4-35

4

Operation

(3) Changes in Output Force during External Force Limiting

Changes in output force when external force limit is set to 800% are shown with the waveform of Un monitor

or SigmaWin+.

In this example, the linear servomotor movement direction is Pn000.0 = 0 (linear scale counting up direction =

forward).

Note: The waveform reverses in case of analog monitor (CN5) output.

4.4.3 Checking Output Force Limiting during Operation

The following signal can be output to indicate that the linear servomotor output force is being limited.

For the allocation method, refer to 3.3.2 Output Signal Allocation.

/P-CL (Forward external force limit input)

OFF

ON

/N-CL

(Reverse external

force limit input)

OFF

ON

Pn402

Pn403

0

Force

Speed

Pn403

0

Pn404

Pn402

Force

Speed

0

Pn403

Pn405

Pn402

Force

Speed

0

Pn403

Pn405

Pn404

Pn402

Force

Speed

Type

Signal Name

Connector

Pin Number

Setting

Meaning

Output

/CLT

Must be allocated

ON (close)

Linear servomotor output force is being
limited.

OFF (open)

Force is not being limited.