Yaskawa Sigma-5 User Manual: Design and Maintenance - Linear Motors User Manual
Page 122

4 Operation
4.3.3 Digital Operator Display during Testing without Motor
4-32
4.3.3 Digital Operator Display during Testing without Motor
The mark (
∗) is displayed before status display to indicate the test without motor operation is in progress.
(Example: Test without motor in progress)
Note: The test without motor status is not displayed during alarm occurs (A.).
Display
Status
*RUN
Power is supplied to the motor.
*BB
Power to the motor is OFF.
*
P DET
Detecting the polarity.
*PT NT
Forward or reverse run is prohibited.
*P-OT
Running in the forward direction is prohibited.
*N-OT
Running in the reverse direction is prohibited.
*HBB
In hard-wire base block (safety) state.
∗ B B
− P R M / M O N −
U n 0 0 0 =
0
0 0 0 0 0
U n 0 0 2 =
0
0 0 0 0 0
U n 0 0 8 =
0
0 0 0 0 0 0 0 0 0 0
U n 0 0 D =
0
0 0 0 0 0 0 0 0 0 0