6.12 Write Prohibited Setting (Fn010)

6-23

6

Utility Functions (Fn

)

(2) Operating Procedure

Follow the steps below to set

write prohibited

or

write permitted.

Setting values are as follows:

“P.

0000

: Write permitted (Releases write prohibited mode.) [Factory setting]

“P.

0001

: Write prohibited (Parameters become write prohibited from the next power ON.)

Step

Display Example

Keys

Operation

1

Press the

Key to view the main menu for the util-

ity function mode.
Use the

or

Key to move through the list,

select Fn010.

2

Press the

Key. The display switches to the exe-

cution display of Fn010.

3

Press the

Key to select one of the following set-

tings.
P.0000: Write permitted [Factory setting]

P.0001: Write prohibited

4

Press the

Key to save the setting value in the

SERVOPACK. When the saving is completed,
“DONE” is displayed in the status display.

5

Press the

Key to return to the Utility Function

Mode main menu.

6

Turn OFF the SERVOPACK power supply and then turn it ON again to validate the new setting.

B B

− F U N C T I O N −

F n 0 0 F : C u r M a n u A d j
F n 0 1 0 : P r m P r o t e c t
F n 0 1 1 : M o t o r I n f o
F n 0 1 2 : S o f t V e r

B B
P a r a m e t e r

W r i t e P r o t e c t

P . 0 0 0 0

B B
P a r a m e t e r

W r i t e P r o t e c t

P . 0 0 0 1

D O N E

P a r a m e t e r

W r i t e P r o t e c t

P . 0 0 0 1

B B

− F U N C T I O N −

F n 0 0 F : C u r M a n u A d j
F n 0 1 0 : P r m P r o t e c t
F n 0 1 1 : M o t o r I n f o
F n 0 1 2 : S o f t V e r