Yaskawa Sigma-5 User Manual: Design and Maintenance - Linear Motors User Manual

Page 272

Advertising
background image

8.1 Troubleshooting

8-21

8

T

roubleshooting

A.E61:
Command Option

Module IF

Synchronization Error

3

The timing of synchronization
between the SERVOPACK and
command option module changed
due to change in the communica-
tions cycle of the host controller
connected to the command option
module.

Turn the power supply OFF and
then ON again. If the alarm occurs
again, restart communications pro-
cessing from the host controller.

The connection between the
SERVOPACK and the command
option module is faulty.

Check the connection between the
SERVOPACK and the command
option module.

Correctly connect the command
option module.

A command option module fault
occurred.

Replace the command option mod-
ule.

A SERVOPACK fault occurred.

Replace the SERVOPACK.

A.E70:
Command Option

Module Detection

Failure

The connection between the
SERVOPACK and the command

option module is faulty.

Check the connection between the
SERVOPACK and the command
option module.

Correctly connect the command
option module.

The command option module is
not connected.

Correctly connect the command
option module.

A command option module fault
occurred.

Replace the command option mod-
ule.

A SERVOPACK fault occurred.

Replace the SERVOPACK.

A.E71:
Safety Option Module

Detection Failure

The connection between the

SERVOPACK and the safety
option module is faulty.

Check the connection between the

SERVOPACK and the safety option
module.

Correctly connect the safety option
module.

The safety option module was
disconnected.

Execute Fn014 (Resetting configu-
ration error of option module) with
using the digital operator or Sig-
maWin+ and turn the power supply
OFF and then ON again.

A safety option module fault

occurred.

Replace the safety option module.

A SERVOPACK fault occurred.

Replace the SERVOPACK.

A.E72:
Feedback Option

Module Detection

Failure

The connection between the
SERVOPACK and the feedback
option module is faulty.

Check the connection between the
SERVOPACK and the feedback
option module.

Correctly connect the feedback
option module.

The feedback option module was
disconnected.

Execute Fn014 (Resetting configu-
ration error of option module) with
the digital operator or SigmaWin+
and turn the power supply OFF and
then ON again.

A feedback option module fault
occurred.

Replace the feedback option mod-
ule.

A SERVOPACK fault occurred.

Replace the SERVOPACK.

A.E73:
Unsupported Option

Module

A command option module fault
occurred.

Replace the command option mod-
ule.

A unsupported command option
module was connected.

Refer to the catalog of the con-
nected command option module.

Connect a compatible command
option module.

A.E74:
Unsupported Safety

Option Module

A safety option module fault
occurred.

Replace the safety option module.

A unsupported safety option
module was connected.

Refer to the catalog of the con-
nected safety option module.

Connect a compatible safety option
module.

Alarm:

Alarm Name

Cause

Investigative Actions

Corrective Actions

Advertising