4.5 Setting Absolute Linear Scale

4-41

4

Operation

(3) Detailed Signal Specifications

The detailed signal specifications are shown below.

„

PAO Serial Data Specifications.

(4) Transferring Alarm Contents

If an absolute linear scale is used, the contents of alarms detected by the SERVOPACK can be transmitted in

serial data to the host controller from the PAO output when the sensor ON command is changed from ON to

OFF.

Note: Sensor ON command cannot be turned OFF while the servomotor power is ON.

An example of alarm contents output is shown below.

Data Transfer

Method

Start-stop Synchronization (ASYNC)

Baud rate

9600 bps

Start bits

1 bit

Stop bits

1 bit

Parity

Even

Character code

ASCII 7-bit code

Data format

8 characters, as shown below.

Note 1. The absolute data range is “P+00000” (CR) or “P-00000” (CR).

2. The serial data range is "-32768" to "+32767." When this range is

exceeded, the data changes from "+32767" to "-32768" or from "-
32768" to "+32767."

3. The signs are inversed when in reverse direction mode (Pn000.0 =

1).

Data

Start bit

Even parity

Movement amount
data in five digits

"+" or " - "

"0" to "9"

"CR"

"P"

Stop bit

0 0 0 0 0 1 0 1 0 1

CR

Sensor ON
Command

OFF

Error detection

ON

Incremental pulse

Serial Data

Enlarged view

Panel Display

PAO
Output

Serial Data Format

Upper 2 digits

A

L M 5 1 . CR

" " " " " " " " " " " " " "

or

Overspeed