2) failure in operation – Yaskawa Sigma-5 User Manual: Design and Maintenance - Linear Motors User Manual

Page 165

Advertising
background image

5.3 Advanced Autotuning (Fn201)

5-21

5

Adjustments

(2) Failure in Operation

This section describes the causes and corrective actions in case the operation has not been successfully com-

pleted.

„

If “NO-OP” is shown

„

If “Errors” is shown

„

Errors during Calculation of Mass Ratio

The following table shows the probable causes of errors that may occur during the calculation of the mass

ratio with the Jcalc set to ON, along with corrective actions for the errors.

Probable Cause

Corrective Actions

The main circuit power supply was OFF.

Turn ON the main circuit power supply.

An alarm or warning occurred.

Remove the cause of the alarm or the warning.

Overtraveling occurred.

Remove the cause of the overtravel.

Gain setting 2 was selected by gain switching.

Turn OFF the automatic gain switching.

The HWBB function operated.

Cancel the HWBB function.

Error

Probable Cause

Corrective Actions

The gain adjustment was

not successfully

completed.

• Machine vibration is occurring or the

positioning completed signal (/COIN) is
repeatedly turning ON and OFF.

• Increase the set value for Pn522.
• Change the mode from 2 to 3.
• If machine vibration occurs, suppress the

vibration with the anti-resonance control
adjustment function and the vibration
suppression function.

An error occurred during

the calculation of the

mass ratio.

Refer to the following table „ Errors during Calculation of Mass Ratio.

Travel distance setting

error

The travel distance is set to approximately 5
mm or less, which is less than the minimum
adjustable travel distance.

Increase the travel distance. It is recom-
mended to set the travel distance to around
90 mm.

The positioning

completed signal (/COIN)

did not turn ON within

approximately 10 seconds

after positioning

adjustment was

completed.

The positioning completed width is too nar-
row or the proportional control (P control)

is being used.

• Increase the set value for Pn522.
• If P control is used, turn OFF the /P-CON

signal.

A setting error occurred in

the mass ratio calculation

when the tuning-less

function was activated.

When the tuning-less function was
activated, Jcalc was set to OFF, so the mass
ratio was not calculated.

• Turn OFF the tuning-less function.
• Set Jcalc to ON, so the mass ratio will be

calculated.

Error

Display

Cause

Corrective Action

Err1

The SERVOPACK started calculating the mass
ratio, but the calculation was not completed.

• Increase the speed loop gain (Pn100).
• Increase the STROKE (travel distance).

Err2

The mass ratio fluctuated greatly and did not
converge within 10 tries.

Set the calculation value based on the machine specifi-
cations in Pn103 and execute the calculation with the
Jcalc set to OFF.

Err3

Low-frequency vibration was detected.

Double the mass calculating start level (Pn324).

Err4

The force limit was reached.

• Increase the force limit value.
• Double the mass calculating start level (Pn324).

Err5

While calculating the mass ratio, the speed con-
trol was set to proportional control with P-CON
input.

Operate the SERVOPACK with PI control while calcu-
lating the mass ratio.

Advertising