Yaskawa Sigma-5 User Manual: Design and Maintenance - Linear Motors User Manual

Page 307

Advertising
background image

9 Appendix

9.1.2 Parameters

9-22

Pn587

Polarity Detection for Absolute Scale
Selection

0000 to 0001

0000

Immediately

Setup

Pn600

Regenerative Resistor Capacity

∗2

Depends on

SERVOPACK

Capacity

∗3

10 W

0

Immediately

Setup

3.7.2

Pn601

Reserved (Do not change.)

0

Pn800 to
Pn95F

4

Reserved (Do not change.)

0

∗2. Normally set to “0.” When using an external regenerative resistor, set the capacity (W) of the regenerative resistor.

∗3. The upper limit is the maximum output capacity (W) of the SERVOPACK.

∗4. For details on Pn800 to Pn95F, refer to the manual of the connected Command Option Module.

Parameter

No.

Name

Setting

Range

Units

Factory

Setting When Enabled Classification

Refer-

ence

Section

4th

digit

3rd

digit

2nd

digit

1st

digit

n.

Polarity Detection for Absolute Scale Selection

0
1

Reserved (Do not change.)

Does not detect polarity.

Detects polarity.

Reserved (Do not change.)

Reserved (Do not change.)

Advertising