Yaskawa Sigma-5 User Manual: Design and Maintenance - Linear Motors User Manual

Page 301

Advertising
background image

9 Appendix

9.1.2 Parameters

9-16

Pn50B

Input Signal Selection 2

0000 to FFFF

8882

After restart

Setup

Pn50C

Reserved (Do not change.)

8888

Pn50D

Reserved (Do not change.)

8888

Parameter

No.

Name

Setting

Range

Units

Factory

Setting

When

Enabled

Classification Reference

Section

4th
digit

3rd
digit

2nd
digit

1st
digit

n.

/P-CL Signal Mapping

N-OT Signal Mapping

0

1

2

3

4

5

6

7

8

9

A

B

C

D

E

F

Valid when CN1-13 input signal is ON (L-level).

Valid when CN1-7 input signal is ON (L-level).

Valid when CN1-8 input signal is ON (L-level).

Valid when CN1-9 input signal is ON (L-level) .

Valid when CN1-10 input signal is ON (L-level).

Valid when CN1-11 input signal is ON (L-level).

Valid when CN1-12 input signal is ON (L-level).

Reverse run prohibited.

Reverse run allowed.

Valid when CN1-13 input signal is OFF (H-level).

Valid when CN1-7 input signal is OFF (H-level).

Valid when CN1-8 input signal is OFF (H-level).

Valid when CN1-9 input signal is OFF (H-level).

Valid when CN1-10 input signal is OFF (H-level).

Valid when CN1-11 input signal is OFF (H-level).

Valid when CN1-12 input signal is OFF (H-level).

0 to F

/N-CL Signal Mapping

Reserved (Do not change.)

0 to F

Same as N-OT signal mapping

Same as N-OT signal mapping

(Refer to 4.2.3)