Yaskawa Sigma-5 User Manual: Design and Maintenance - Linear Motors User Manual
Page 90

3 Wiring and Connection
3.8.3 Connecting AC/DC Reactor for Harmonic Suppression
3-44
3.8.3 Connecting AC/DC Reactor for Harmonic Suppression
The SERVOPACK has reactor connection terminals for power supply harmonic suppression.
As for the precautions on selecting an AC or DC reactor and its specifications, refer to
Σ
-V series Product Cat-
alog (KAEP S800000 42).
Connect a reactor as shown in the following diagram.
Note 1. Connection terminals for DC reactor 1 and 2 are short-circuited at shipment. Remove the lead wire for
short-circuit, and connect a DC reactor.
2. AC and DC reactors are not provided. (option)
3. A SERVOPACK with a single-phase, 100-V power supply input cannot be connected to a DC reactor.
SERVOPACK AC Reactor with
100-VAC Power Supply Input
SERVOPACK DC Reactor with
200/400-VAC Power Supply Input
L1
L2
SERVOPACK
AC reactor
Power
supply
1
2
SERVOPACK
DC reactor