6.7 Clearing Alarm History (Fn006)

6-15

6

Utility Functions (Fn

)

6.7 Clearing Alarm History (Fn006)

The clear alarm history function deletes all of the alarm history recorded in the SERVOPACK.

Note: The alarm history can be deleted only with this function. The alarm history is not deleted when the alarm reset is

executed or the main circuit power supply of the SERVOPACK is turned OFF.

Follow the steps below to clear the alarm history.

Step

Display Example

Keys

Operation

1

Press the

Key to view the main menu for the util-

ity function mode.
Use the

or

Key to move through the list,

select Fn006.

2

Press the

Key. The display is switched to the

execution display of Fn006.
Note:
If the display is not switched and “NO-OP” is dis-
played in the status display, the Write Prohibited Set-

ting (Fn010 = 0001) is set. Check the setting and
reset. (Refer to 6.12.)

3

Press the

Key to clear the alarm history.

While clearing the data, “DONE” is displayed in the
status display. After the data has been successfully
cleared, “BB” is displayed.
Note:
Press the

Key not to clear the alarm history. The

display returns to the Utility Function Mode main
menu.