5 Adjustments

5.9.2 Using the Mode Switch (P/PI Switching)

5-62

<Example>
If the mode switch function is not being used and the SERVOPACK is always operated with PI control, the

speed of the linear servomotor may overshoot due to force saturation during acceleration or deceleration. The
mode switch function suppresses force saturation and eliminates the overshooting of the motor speed.

„

Using the Speed Reference Level to Switch Modes

With this setting, the speed loop is switched to P control when the value of speed reference input exceeds the

speed set in Pn181.

<Example>
In this example, the mode switch is used to reduce the settling time. It is necessary to increase the speed loop

gain to reduce the settling time. Using the mode switch suppresses overshooting when speed loop gain is

increased.

Without Mode Switching

With Mode Switching

Overshoot

Overshoot

Motor
speed

Time

Motor
speed

Time

Speed reference

Speed

Motor
speed

Time

P Control

PI Control

Pn181

PI

Without Mode Switching

With Mode Switching

Motor
speed

Speed reference

Long settling time

Increase speed loop gain.

Settling time

Motor
speed

Overshoot

Overshoot

Motor
speed

Time

Motor
speed

Time

Time