9.1 List of Parameters
9-15
9
Appendix
Pn50A
Input Signal Selection 1
0000 to FFF1
−
1881
After restart
Setup
−
Parameter
No.
Name
Setting
Range
Units
Factory
Setting
When
Enabled
Classification Reference
Section
4th
digit
3rd
digit
2nd
digit
1st
digit
n.
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
Valid when CN1-13 input signal is ON (L-level).
Valid when CN1-7 input signal is ON (L-level).
Valid when CN1-8 input signal is ON (L-level).
Valid when CN1-9 input signal is ON (L-level).
Valid when CN1-10 input signal is ON (L-level).
Valid when CN1-11 input signal is ON (L-level).
Valid when CN1-12 input signal is ON (L-level).
Forward run prohibited.
Forward run allowed.
Valid when CN1-13 input signal is OFF (H-level).
Valid when CN1-7 input signal is OFF (H-level).
Valid when CN1-8 input signal is OFF (H-level).
Valid when CN1-9 input signal is OFF (H-level).
Valid when CN1-10 input signal is OFF (H-level).
Valid when CN1-11 input signal is OFF (H-level).
Valid when CN1-12 input signal is OFF (H-level).
P-OT Signal Mapping
Reserved (Do not change.)
Reserved (Do not change.)
Reserved (Do not change.)
(Refer to 4.2.3)