5.2 Tuning-less Function

5-11

5

Adjustments

∗ Operate using SigmaWin+.

(3) Automatically Setting the Notch Filter

Usually, set this function to Auto Setting. (The notch filter is factory-set to Auto Setting.)
If this function is set to Auto Setting, vibration will be detected automatically and the notch filter will be set.

Set this function to Not Auto Setting only if you do not change the notch filter setting before executing tuning-
less function.

(4) Tuning-less Level Settings

Two tuning-less levels are available: the tuning-less adjustment level and tuning-less load level. Both level can

be set in the Fn200 utility function and in the Pn170 parameter.

„

Tuning-less Adjustment Level

The servo gain can be adjusted between rigidity level 4 (high gain) and rigidity level 0 (low gain) by changing

the tuning-less adjustment level with the utility function and parameter settings.

a) By using the utility function

To change the setting, refer to 5.2.2 Tuning-less Levels Setting (Fn200) Procedure.

b) By using the parameter

Mechanical analysis *

Available

While this function is being used, the tuning-
less function cannot be used temporarily.

Control Function

Availability

Remarks

Parameter

Meaning

When Enabled

Classification

Pn460

n.†0††

Does not set the 2nd notch filter automatically using

the utility function.

Immediately

Tuning

n.†1††

sets the 2nd notch filter automatically using the util-
ity function.
[Factory setting]

Tuning Level

Meaning

Level 0

Rigidity level 0

Level 1

Rigidity level 1

Level 2

Rigidity level 2

Level 3

Rigidity level 3

Level 4

Rigidity level 4 [Factory setting]

Parameter

Meaning

When Enabled

Classification

Pn170

n.†0††

Rigidity level 0 (Level 0)

Immediately

Setup

n.†1††

Rigidity level 1 (Level 1)

n.†2††

Rigidity level 2 (Level 2)

n.†3††

Rigidity level 3 (Level 3)

n.†4††

Rigidity level 4 (Level 4) [Factory setting]