4 Operation

4.2.9 Instantaneous Power Interruption Settings

4-24

4.2.9 Instantaneous Power Interruption Settings

Determines whether to continue operation or turn the linear servomotor’s power OFF when the power supply
voltage is interrupted.

An instantaneous power interruption will be detected when the main circuit power supply is turned OFF. If the

time required to restore the main circuit power supply is less than the parameter set value, the servo will con-
tinue operating. If the restoration time is the equal to or greater than the set value, the linear servomotor’s

power is turned OFF.

If the uninterruptible power supplies are used for the control power supply and main circuit power supply, the

SERVOPACK can withstand an instantaneous power interruption period in excess of 1000 ms.

4.2.10 Motor Maximum Speed

By setting the linear servomotor maximum speed to a lower speed, the following effects can be obtained.

• More delicate speed control and more strict protection by generating the overspeed alarm (A.510)
• Allows the upper limit of Encoder Output Resolution (Pn281) to be set higher.

For details, refer to 4.2.5 Encoder Output Pulse.

Pn509

Instantaneous Power Cut Hold Time

Classification

Setting Range

Setting Unit

Factory Setting

When Enabled

20 to 1000

1 ms

20

Immediately

Setup

• The holding time of the control power supply for the 200 V SERVOPACK is approxi-

mately 100 ms, but the time of the control power supply for the 100 V SERVOPACKs
is approximately 65 ms. If the control power supply makes control impossible during
an instantaneous power interruption, the same operation will be performed as for nor-
mally turning OFF the power supply, and the setting of the parameter will be ignored.

• The holding time of the main circuit power supply varies with the output of the SER-

VOPACK. If the load on the linear servomotor is large and an undervoltage alarm
(A.410) occurs, the parameter will be ignored.

• The holding time of the control power supply (24 VDC) for the 400 V SERVOPACKs

depends on the capability of the power supply (not included). Check the power supply
before using the application.

Speed

Position

Force

Instantaneous power interruption

Set value for Pn509

≥ OFF time (t)

OFF time (t)

Power OFF

Set value for
Pn509

≥ OFF time (t)

Set value for Pn509 <
OFF time (t)

Main circuit
power supply

Set value for
Pn509

Linear
servomotor
status

Power ON

Instantaneous power interruption

Set value for Pn509 < OFF time (t)

Forced
OFF.

OFF time (t)

Main circuit
power supply

Set value for
Pn509

Linear
servomotor
status

Power ON

Operation
continues.

Depends on the functions of
the Command Option
Module.

Motor Maximum Speed

 

 

Classification

Pn385

Setting Range

Setting Unit

Factory Setting

When Enabled

1 to 100

100 mm/s

50

After restart

Setup

Speed

Position

Force