9.1 List of Parameters

9-7

9

Appendix

Pn00C

Application Function Select Switch C 0000 to 0111

0000

After restart

Setup

Pn00D

Application Function Select Switch D 0000 to 0001

0000

After restart

Setup

Pn010

Axis Address Selection

0000 to 007F

0001

After restart

Setup

Pn080

Application Function Select Switch
80

0000 to 1111

0000

After restart

Setup

Parameter

No.

Name

Setting

Range

Units

Factory

Setting

When

Enabled

Classification Reference

Section

Reserved (Do not change.)

Reserved (Do not change.)

4th
digit

3rd
digit

2nd
digit

1st
digit

n.

0

1

Selection of Test without Motor

Disables Test without motor.

Enables Test without motor.

0

0

Encoder Type for Test without Motor

Incremental linear scale

Absolute linear scale

(Refer to 4.3.3)

(Refer to 4.3.3)

Reserved (Do not change.)

n.

Reserved (Do not change.)

0

1

Stand-alone Mode (Test Operation) Selection

Enables connection with the command option module.

Disables connection with the command option module.

Reserved (Do not change.)

4th
digit

3rd
digit

2nd
digit

1st
digit

0

1

Motor Phase Selection

Calculation Method for Maximum Speed or Divided Output Pulses

4th
digit

3rd
digit

2nd
digit

1st
digit

n.

Sets phase A lead as phase sequence of U, V, W.

Sets phase B lead as phase sequence of U, V, W.

Reserved (Do not change.)

0

1

Determines divided output pulses with fixed maximum speed.

Determines maximum speed with fixed divided output pulses.

0

1

Hall Sensor Selection

Enables selection.

Disables selection.

Advertising