9.2 Monitor Modes

9-23

9

Appendix

9.2 Monitor Modes

The following list shows monitor modes available.

∗1. For details, refer to 4.2.4 Electronic Gear.
∗2. Scale pitch = Un084 × 10

Un085

[pm]

Parameter

No.

Content of Display

Unit

Un000

Motor movement speed

mm/s

Un001

Speed reference (for speed control)

mm/s

Un002

Internal force reference (in percentage to the rated force)

%

Un003

Electric angle 1

pulse (linear scale resolution)

Un004

Electric angle 2 (angle from the polarity origin)

deg

Un005

Input signal monitor

Un006

Output signal monitor

Un007

Reference speed (for position control)

mm/s

Un008

Position error (for position control)

reference unit

Un009

Accumulated load ratio (in percentage to the rated force: effec-
tive force in cycle of 10 seconds)

%

Un00A

Regenerative load ratio (in percentage to the processable
regenerative power: regenerative power consumption in cycle
of 10 seconds)

%

Un00B

Power consumed by DB resistance
(in percentage to the processable power at DB activation: dis-
played in cycle of 10 seconds)

%

Un00C

Reference counter

reference unit

Un00D

Feedback pulse counter

pulse (linear scale resolution)

*1

Un010

Maximum allowable motor speed or maximum allowable

encoder output resolution

Un011

Hall sensor signal monitor

Un012

Total operation time

100 ms

Un013

Feedback pulse counter

reference unit

Un014

Effective gain monitor (gain setting 1 = 1, gain setting 2 = 2)

Un015

Safety I/O signal monitor

Un020

Motor rated speed

mm/s

Un021

Motor maximum speed

mm/s

Un084

Linear scale pitch

*2

pm

Un085

Linear scale pitch index

*2

Advertising