6 initializing parameter settings (fn005) – Yaskawa Sigma-5 User Manual: Design and Maintenance - Linear Motors User Manual

Page 225

Advertising
background image

6 Utility Functions (Fn†††)

6-14

6.6 Initializing Parameter Settings (Fn005)

This function is used when returning to the factory settings after changing parameter settings.

Follow the steps below to initialize the parameter setting.

• Be sure to initialize the parameter settings while the linear servomotor power is OFF

.

• After initialization, turn OFF the SERVOPACK power supply and then turn ON again

to validate the settings.

• The parameters of the option module will not be initialized. For information on how to

initialize the parameters of the option module, refer to the manual of the connected
option module.

Step

Display Example

Keys

Operation

1

Press the

Key to view the main menu for the util-

ity function mode.
Use the

or

Key to move through the list,

select Fn005.

2

Press the

Key. The display is switched to the

execution display of Fn005.
Note:
If the display is not switched and “NO-OP” is dis-
played in the status display, change the following set-
tings. (Refer to 6.12.)

• If Write Prohibited is set in Fn010:

→ Cancel the Write Prohibited setting.

• If a servo ON command is input:

→ Send a servo OFF command.

3

Press the

Key to initialize parameters.

During initialization, “Parameter Init” is blinking in
the display.
After the initialization is completed, “Parameter Init”
stops blinking and the status display changes as fol-
lows: “BB” to “DONE.”
Note:
Press the

Key not to initialize parameters. The

display returns to the Utility Function Mode main

menu.

4

Turn OFF the SERVOPACK power supply and then turn it ON again to validate the new setting.

㧮㧮ޓޓޓޓޓ㧙㧲㨁㧺㧯㨀㧵㧻㧺㧙
㧲㨚㧜㧜㧠㧦㧼㨞㨛㨓㨞㨍㨙ޓ㧶㧻㧳
㧲㨚㧜㧜㧡㧦㧼㨞㨙ޓ㧵㨚㨕㨠

㧲㨚㧜㧜㧤㧦㧹㨠㨡㨞㨚ޓ㧯㨘㨞

㧲㨚㧜㧜㧢㧦㧭㨘㨙㧴㨕㨟㨠ޓ㧯㨘㨞

㧮㧮
ޓ㧼㨍㨞㨍㨙㨑㨠㨑㨞ޓ㧵㨚㨕㨠
ޓޓ㧿㨠㨍㨞㨠ޓ㧦㨇㧰㧭㨀㧭㨉
ޓޓ㧾㨑㨠㨡㨞㨚㧦㨇㧿㧱㨀㨉

㧮㧮
ޓ㧼㨍㨞㨍㨙㨑㨠㨑㨞ޓ㧵㨚㨕㨠
ޓޓ㧿㨠㨍㨞㨠ޓ㧦㨇㧰㧭㨀㧭㨉
ޓޓ㧾㨑㨠㨡㨞㨚㧦㨇㧿㧱㨀㨉

Advertising