3) related functions – Yaskawa Sigma-5 User Manual: Design and Maintenance - Linear Motors User Manual

Page 181

Advertising
background image

5.5 One-parameter Tuning (Fn203)

5-37

5

Adjustments

(3) Related Functions

This section describes functions related to one-parameter tuning.

„

Notch Filter

Usually, set this function to Auto Setting. (The notch filter is factory-set to Auto Setting.)

If this function is set to Auto Setting, vibration will be detected automatically and the notch filter will be set.

Set this function to Not Auto Setting only if you do not change the notch filter setting before executing one-

parameter tuning.

„

Anti-Resonance Control Adjustment Function

This function reduces low vibration frequency; which the notch filter does not detect.

Usually, set this function to Auto Setting. (The anti-resonance control is factory-set to Auto Setting.)
When this function is set to Auto Setting, vibration will be automatically detected during one-parameter tun-

ing and anti-resonance control will be automatically adjusted and set.

“ARES” will blink on the digital operator when anti-resonance control adjustment function is set.

Parameter

Function

When Enabled

Classification

Pn460

n.†††0

Does not set the 1st notch filter automatically using
the utility function.

Immediately

Tuning

n.†††1

Sets the 1st notch filter automatically using the utility

function.
[Factory setting]

n.†0††

Does not set the 2nd notch filter automatically using
the utility function.

n.†1††

Sets the 2nd notch filter automatically using the util-
ity function.
[Factory setting]

Parameter

Function

When Enabled

Classification

Pn160

n.††0†

Does not use the anti-resonance control automatically
using the utility function.

Immediately

Tuning

n.††1†

Uses the anti-resonance control automatically using
the utility function.
[Factory setting]

㧾㨁㧺   ̆㧻㨚㨑㧼㨞㨙㨀㨡㨚̆
㧲㧲ޓ㧸㧱㨂㧱㧸ޓ㧩ޓ㧜㧜㧡㧜
㧲㧮ޓ㧸㧱㨂㧱㧸ޓ㧩ޓ㧜㧜㧠㧜ޓ
ޓ
ޓ㧺㧲㧝ޓ㧺㧲㧞ޓޓޓ㧭㧾㧱㧿

Advertising