Yaskawa Sigma-5 User Manual: Design and Maintenance - Linear Motors User Manual

Page 312

Advertising
background image

9.3 Parameter Recording Table

9-27

9

Appendix

Pn48E

10 mm

Polarity Detection Range

Immediately

Pn490

100%

Polarity Detection Load Level

Immediately

Pn495

100%

Polarity Detection Confirmation

Force Reference

Immediately

Pn498

10 deg.

Polarity Detection Allowable Error
Range

Immediately

Pn501

10

Reserved Parameter

Pn506

0 ms

Brake Reference - Servo OFF Delay
Time

Immediately

Pn508

50 ms

Waiting Time for Brake Signal When
Motor Running

Immediately

Pn509

20 ms

Instantaneous Power Cut Hold time

Immediately

Pn50A

1881

Input Signal Selection 1

After restart

Pn50B

8822

Input Signal Selection 2

After restart

Pn50C

8888

Reserved Parameter

Pn50D

8888

Reserved Parameter

Pn50E

0000

Output Signal Selection 1

After restart

Pn50F

0100

Output Signal Selection 2

After restart

Pn510

0000

Output Signal Selection 3

After restart

Pn511

6543

Input Signal Selection 5

After restart

Pn512

0000

Output Signal Inverse Setting

After restart

Pn513

0000

Reserved Parameter

Pn517

0000

Reserved Parameter

Pn51E

100%

Excessive Position Error Warning

Level

Immediately

Pn520

5242880

reference unit

Excessive Position Error Alarm Level

Immediately

Pn522

7

reference unit

Positioning Completed Width

Immediately

Pn524

1073741824

reference unit

NEAR Signal Width

Immediately

Pn526

5242880

reference unit

Excessive Position Error Alarm Level
at Servo ON

Immediately

Pn528

100%

Excessive Position Error Warning
Level at Servo ON

Immediately

Pn52B

20%

Overload Warning Level

Immediately

Pn52C

100%

Derating of Base Current at Detecting
Overload of Motor

After restart

Pn52F

0FFF

Monitor Display at Power ON

Immediately

Pn530

0000

Program JOG Operation Related
Switch

Immediately

Pn531

32768

reference unit

Program JOG Movement Distance

Immediately

Pn534

100 ms

Program JOG Acceleration/Decelera-
tion Time

Immediately

Pn535

100 ms

Program JOG Waiting Time

Immediately

Pn536

1 time

Number of Times of Program JOG
Movement

Immediately

Pn550

0.0 V

Analog Monitor 1 Offset Voltage

Immediately

Pn551

0.0 V

Analog Monitor 2 Offset Voltage

Immediately

Pn552

×1

Analog Monitor Magnification (

×1)

Immediately

Parame-

ter

Factory

Setting

Name

When

Enabled

Advertising