3 connecting to sgdv-***de5a servopack, 3 connecting to sgdv-de5a servopack – Yaskawa Sigma-5 User Manual: Design and Maintenance - Linear Motors User Manual
Page 37

1.6 Examples of Servo System Configurations
1-17
1
Outline
1.6.3 Connecting to SGDV-DE5A SERVOPACK
∗1. Use a 24-VDC power supply with double insulation or reinforced insulation. (The power supply is not included)
∗2. Before connecting an external regenerative resistor to the SERVOPACK, refer to 3.7 Regenerative Resistors Connec-
tions.
Noise filter
Molded-case
circuit breaker
(MCCB)
Magnetic
contactor
I/O signal cable
Power supply
Three-phase 400 VAC
R S T
Protects the power
supply line by shutting
the circuit OFF when
overcurrent is detected.
Used to eliminate
external noise from
the power line.
Turns the servo
ON and OFF.
Install a surge
absorber.
Personal
computer
Cable for connecting
personal computer
Digital
operator
Cable for connecting
digital operator
When not using the safety function,
use the SERVOPACK with the
safety function’s jumper connector
(JZSP-CVH05-E provided as an
accessory) interted.
When using the safety function,
insert a connection cable specially
for the safety function.
Safety function
devices
24-VDC
power supply
*2
SGDV-
DE5A
SERVOPACK
*1
External device
such as external
LED indicator
Command Option
Module
Linear servomotor
with core
Linear scale
(not included)
Cable for connecting
hall sensor
Main circuit cable for linear servomotor
Serial converter unit
Cable for connecting
serial converter unit
Cable for connecting
linear scale
Regenerative
resistor