1.6 Examples of Servo System Configurations

1-17

1

Outline

1.6.3 Connecting to SGDV-†††DE5A SERVOPACK

∗1. Use a 24-VDC power supply with double insulation or reinforced insulation. (The power supply is not included)

∗2. Before connecting an external regenerative resistor to the SERVOPACK, refer to 3.7 Regenerative Resistors Connec-

tions.

Noise filter

Molded-case
circuit breaker
(MCCB)

Magnetic
contactor

I/O signal cable

Power supply
Three-phase 400 VAC

R S T

Protects the power
supply line by shutting
the circuit OFF when
overcurrent is detected.

Used to eliminate
external noise from
the power line.

Turns the servo
ON and OFF.
Install a surge
absorber.

Personal
computer

Cable for connecting
personal computer

Digital
operator

Cable for connecting
digital operator

When not using the safety function,
use the SERVOPACK with the
safety function’s jumper connector
(JZSP-CVH05-E provided as an
accessory) interted.

When using the safety function,
insert a connection cable specially
for the safety function.

Safety function
devices

24-VDC
power supply

*2

SGDV-

DE5A

SERVOPACK

*1

External device
such as external
LED indicator

Command Option
Module

Linear servomotor
with core

Linear scale
(not included)

Cable for connecting
hall sensor

Main circuit cable for linear servomotor

Serial converter unit

Cable for connecting
serial converter unit

Cable for connecting
linear scale

Regenerative
resistor