Yaskawa Sigma-5 User Manual: Design and Maintenance - Linear Motors User Manual

Page 279

Advertising
background image

8 Troubleshooting

8.2.2 Troubleshooting of Warnings

8-28

A.95B

Command

Option Module

IF Command

Warning 2

The command option
module sent a command
that is not supported by
the SERVOPACK.

Send a command that is supported by
the SERVOPACK.

A.95D

Command

Option Module

IF Command

Warning 4

A latch command was

sent from the command
option module during
latch operation.

Review the input sequence for the
latch command.

A.95E

Command

Option Module

IF Command

Warning 5

An unallowed com-
mand combination was

output to the SERVO-
PACK from the com-
mand option module.

Send a command that can be com-
bined.

A.95F

Command

Option Module

IF Command

Warning 6

The command option
module sent a command
that is not supported by
the SERVOPACK.

Send a command that is supported by
the SERVOPACK.

A.960

Command

Option Module

IF

Communications

Warning

An error occurred in

communications
between the SERVO-
PACK and command
option module due to
noise.

Take measures against noise.

The connection between
the SERVOPACK and
the command option
module is faulty.

Check the connection between the
SERVOPACK and the command
option module.

Correctly connect the command
option module.

A command option
module fault occurred.

Replace the command option module.

A SERVOPACK fault
occurred.

Replace the SERVOPACK.

Warning

Display

Warning Name

Situation at Warning

Occurrence

Cause

Corrective Actions