1.4 SERVOPACK Ratings and Specifications

1-5

1

Outline

I/O

Signals

Encoder Output Pulses

Phase-A, -B, -C: line driver
Encoder output pulse: any setting ratio

Sequence

Input

Input

Signals

which can

be allocated

Number

of

Channels

7 channels

Functions

The signal allocation and positive/negative logic can be
modified.

Forward run prohibited (P-OT), reverse run prohibited (N-
OT), forward force limit (/P-CL), reverse force limit (/N-CL),
general-purpose input signal (/SI0 to /SI6)

*5

Sequence

Output

Fixed

Output

Servo alarm (ALM)

Output

Signals

which can

be allocated

Number

of

Channels

3 channels

Functions

The signal allocation and positive/negative logic can be modi-

fied.

Positioning completion (/COIN), speed coincidence detection

(/V-CMP), linear servomotor movement detection (/TGON),
servo ready (/S-RDY), force limit detection (/CLT), speed
limit detection (/VLT), brake (/BK), warning (/WARN), near
(/NEAR)

Communi-

cations

Function

RS422A

Communi-

cations

(CN3)

Interface

Digital operator (JUSP-OP05A-1-E), personal computer (can be connected
with SigmaWin+), etc.

1:N

Communi-

cations

N = Up to 15 stations possible at RS422A

Axis

Address

Setting

Set by parameter

USB

Communi-

cations

(CN7)

Interface

Personal computer (can be connected with SigmaWin+.)

Communi-

cations

Standard

Complies with standard USB1.1. (12 Mbps)

LED Display

Panel display (seven-segment, 1 digit), CHARGE and POWER indicators

Analog Monitor (CN5)

Number of points: 2
Output voltage:

±

10V DC (linearity effective range

±

8V)

Resolution: 16 bit
Accuracy:

±

20 mV (Typ)

Max. output current:

±

10 mA

Settling time (

±

1%): 1.2 ms (Typ)

Dynamic Brake (DB)

Activated when a servo alarm, overtravel (OT), or hard wire base block
occurs or when the power supply for the main circuit or servomotor is turned
OFF.

Regenerative Processing

Built-in or external regenerative resistor (option)

Overtravel Prevention (OT)

Stop by dynamic brake, deceleration to a stop, or coast to a stop when a P-
OT or an N-OT signal is input

Protection Function

Overcurrent, overvoltage, insufficient voltage, overload, regeneration error,
and so on.

Utility Function

Gain adjustment, alarm history, JOG operation, origin search, and so on.

Safety Function

Input

/HWBB1, /HWBB2: Base Block signal for power module

Output

EDM1: Monitoring status of internal safety circuit (fixed output)

Option Modules

Fully-closed Module and Command Option Module