Snagentredunbkupcop ybootcode, Snagentenablemgmtm odredunstatechangetr ap, Snagentredunbkupboo tload – Brocade Unified IP MIB Reference (Supporting FastIron Release 07.5.00) User Manual

Page 205: Snagentredunswitchov er, System cpu utilization table, Snagentcpuutiltable, Snagentcpuutilslotnu m

Advertising
background image

Unified IP MIB Reference

177

53-1002549-02

System CPU utilization table

System CPU utilization table

The objects in the following table are not supported on the Brocade MLXe, Brocade NetIron MLX,
Brocade NetIron XMR, Brocade NetIron CES, and Brocade NetIron CER series devices. The objects
are supported on the FastIron devices.

snAgentRedunBkupCop
yBootCode
brcdIp.1.1.2.10.1.3
Syntax: Integer

Read-write

If enabled, the backup management module copies the boot code of the
active management module to its boot code flash storage after power
up, and whenever the active management module’s boot code is
updated. The backup management module does not copy the boot code
it is identical to what is already in flash storage:

disabled(0)

enabled(1)

Default: disabled(0)

snAgentEnableMgmtM
odRedunStateChangeTr
ap
brcdIp.1.1.2.10.1.4
Syntax: Integer

Read-write

Indicates if the SNMP agent process has been enabled to generate
management module redundancy state change traps:

disabled(0)

enabled(1)

Default: enabled(1)

snAgentRedunBkupBoo
tLoad
brcdIp.1.1.2.10.1.5
Syntax: Integer

Read-write

Downloads a new boot code from boot flash storage of the active
management module to the backup management module.
In a set operation, enter the value downloadBackup(20) to download
the boot code from the active management module to the backup
management module. A set operation is rejected during a download
until an error or normal state is reached.
One of the following values is returned by a get operation:

normal(1) – No operation.

operationError(17) – Error codes.

downloadBackup(20) – Download boot code from active module to
backup to the backup module.

snAgentRedunSwitchOv
er
brcdIp.1.1.2.10.1.6
Syntax: Integer

Read-write

Switches a backup management module to an active management
module:

other(1)

reset(2) – Resets the backup module to active.

Name, OID, and syntax

Access

Description

Name, OID, and syntax

Access

Description

snAgentCpuUtilTable
brcdIp.1.1.2.11.1

None

The table to list utilization for all CPUs.

snAgentCpuUtilSlotNu
m
brcdIp.1.1.2.11.1.1.1
Syntax: Integer32

Read-only

The slot number of the module that contains the CPU.

Advertising