snSw8021qTagType
brcdIp.1.1.3.1.34
Syntax: Integer32

Read-write Specifies the IEEE802.1q tag type that is embedded in the length or

type field of an Ethernet packet. It specifies that the two octets after
the length or type field in an Ethernet packet are the tag value.
Default: 33024

snSwBroadcastLimit
brcdIp.1.1.3.1.35
Syntax: Integer32

Read-write Specifies the number of broadcast packets per second. This limits the

number of broadcast packets to forward out of the switch ports.
Setting this object to 0 disables the limitation check.
Default: 0

snSwMaxMacFilterPerSyste
m
brcdIp.1.1.3.1.36
Syntax: Integer32
NOTE: This object is not

supported on the
Brocade MLXe
router, Brocade
NetIron MLX,
Brocade NetIron
XMR, Brocade
NetIron CES, and
Brocade NetIron
CER series devices.

Read-only

Specifies the maximum number of MAC filters per system in the MAC
filter table.

snSwMaxMacFilterPerPort
brcdIp.1.1.3.1.37
Syntax: Integer32
NOTE: This object is not

supported on the
Brocade MLXe
router, Brocade
NetIron MLX,
Brocade NetIron
XMR, Brocade
NetIron CES, and
Brocade NetIron
CER series devices.

Read-only

Specifies the maximum number of MAC filters per port in the port MAC
access filter table.

snSwDefaultVLanId
brcdIp.1.1.3.1.38
Syntax: Integer

Read-write Shows the VLAN ID of the default port VLAN.

Valid values: 1 – 4095

snSwGlobalAutoNegotiate
brcdIp.1.1.3.1.39
Syntax: Integer

Read-write Applies only to Gigabit Ethernet ports.

Specifies the negotiation mode of the port:

disable(0) – All Gigabit Ethernet ports are in non negotiation
mode.

enable(1) – All Gigabit Ethernet ports will start auto-negotiation
indefinitely until they succeed.

negFullAuto(2) – All Gigabit Ethernet ports will start with
auto-negotiation. If the negotiation fails, then they will
automatically switch to non-negotiation mode. Gigabit Ethernet
ports on all stackable products except for TurboIron/8 do not
support negFullAuto(2).

other(3)

Default: negFullAuto(2)