256

Unified IP MIB Reference

53-1002549-02

Packet port information table

snPOSInOctets
brcdIp.1.2.14.1.1.1.25
Syntax: OCTET STRING

Read-only

The total number of packets in octets that were received on the
interface, including framing characters.
This object is a 64-bit counter of the ifInOctets object, defined in
RFC 1213. The octet string is in big-endian byte order.

snPOSOutOctets
brcdIp.1.2.14.1.1.1.26
Syntax: OCTET STRING

Read-only

The total number of packets in octets that were transmitted out of
the interface, including framing characters.
This object is a 64-bit counter of the ifOutOctets object, defined in
RFC 1213. The octet string is in big-endian byte order.

snPOSStatsInBitsPerSec
brcdIp.1.2.14.1.1.1.27
Syntax: Gauge

Read-only

The number of bits per second received on the interface over a
five-minute interval.

snPOSStatsOutBitsPerSec
brcdIp.1.2.14.1.1.1.28
Syntax: Gauge

Read-only

The number of bits per second transmitted out of the interface over
a five-minute interval.

snPOSStatsInPktsPerSec
brcdIp.1.2.14.1.1.1.29
Syntax: Gauge

Read-only

The number of packets per second received on the interface over a
five-minute interval.

snPOSStatsOutPktsPerSec
brcdIp.1.2.14.1.1.1.30
Syntax: Gauge

Read-only

The number of packets per second transmitted out of the interface
over a five-minute interval.

snPOSStatsInUtilization
brcdIp.1.2.14.1.1.1.31
Syntax: Integer

Read-only

The network utilization by incoming traffic in hundredths of a
percent over a five-minute interval.
NOTE: This object is not supported.

snPOSStatsOutUtilization
brcdIp.1.2.14.1.1.1.32
Syntax: Integer

Read-only

The network utilization by outgoing traffic in hundredths of a
percent over a five-minute interval.
NOTE: This object is not supported.

snPOSTagType
brcdIp.1.2.14.1.1.1.33
Syntax: Integer

Read-only

Shows whether or not the port has a VLAN tag:

tagged(1) – The port has a VLAN tag. This port can have
multiple VLANs.

untagged(2) – The port is not tagged.

snPOSStatsB1
brcdIp.1.2.14.1.1.1.34
Syntax: Counter

Read-only

Shows the number of received frames that have parity errors at the
section layer of the SONET link.

snPOSStatsB2
brcdIp.1.2.14.1.1.1.35
Syntax: Counter

Read-only

Shows the number of received frames that have parity errors at the
line layer of the SONET link.

snPOSStatsB3
brcdIp.1.2.14.1.1.1.36
Syntax: Counter

Read-only

Shows the number of received frames that have parity errors at the
path layer of the SONET link.

snPOSStatsAIS
brcdIp.1.2.14.1.1.1.37
Syntax: Counter

Read-only

Shows the number of Alarm Indicator Signals (AISs) that were
received by the interface.

snPOSStatsRDI
brcdIp.1.2.14.1.1.1.38
Syntax: Counter

Read-only

Shows the number of Remote Defect Indicator (RDI) signals that
were received by the interface.

Name, OID, and syntax