Snifopticalmonitoringinfotable, Snifopticalmonitoringtemperat ure, Snifopticalmonitoringtxpower – Brocade Unified IP MIB Reference (Supporting FastIron Release 07.5.00) User Manual

Page 240: Snifopticalmonitoringrxpower, Snifopticalmonitoringtxbiascur rent, Optical lane monitoring table

Advertising
background image

212

Unified IP MIB Reference

53-1002549-02

Optical lane monitoring table

Optical lane monitoring table

The following table displays the optical parameters table per lane for a 100G LR4 and LR10 optic.

Name, OID, and syntax

Access

Description

snIfOpticalMonitoringInfoTable
brcdIp.1.1.3.3.6

None

This table lists the instrumented parameters of all optical
interfaces.

snIfOpticalMonitoringTemperat
ure
brcdIp.1.1.3.3.6.1.1
Syntax: Display string

Read-only

This object holds the value of the transmitter laser diode
temperature for the interface. This object indicates the health
of the transmitter. The format is xxx.yyyy C (Celcius), followed by
whether the measured value is normal, high or low alarm, or
high or low warning.
For 100G LR4 and LR10 optic, this object returns the average
temperature for all the lanes.

snIfOpticalMonitoringTxPower
brcdIp.1.1.3.3.6.1.2
Syntax: Display string

Read-only

This object holds the value of the transmitter optical signal
power for the interface, measured in dBm, followed by whether
this is a normal value, or high or low warning or alarm.
For 100G LR4 and LR10 optic, this object returns the
aggregated Tx power for all the lanes.

snIfOpticalMonitoringRxPower
brcdIp.1.1.3.3.6.1.3
Syntax: Display string

Read-only

This object holds the value of the receiver optical signal power
for the interface, measured in dBm, followed by whether this is
a normal value, high or low warning, or alarm.
For 100G LR4 and LR10 optic, this object returns the
aggregated Rx power for all the lanes.

snIfOpticalMonitoringTxBiasCur
rent
brcdIp.1.1.3.3.6.1.4
Syntax: Display string

Read-only

The Tx bias current. It is measured in mA, and is followed by
whether this is a normal value, high or low warning, or alarm.
For 100G LR4 and LR10 optic, this object returns the
aggregated Tx bias current for all the lanes.

Name, OID, and syntax

Access

Description

snIfOpticalLaneMonitoringTa
ble
brcdIp.1.1.3.3.10

None

This table lists the instrumented parameters of all lanes within a
100G optic of type LR4 and LR10.

snIfOpticalLaneMonitoringLa
ne
brcdIp.1.1.3.3.10.1.1
Syntax: Unsigned32

None

This objects is the lane number of the 100G optic. An LR4 has
4-lanes per optic and LR10 has 10-lanes per optic.

snIfOpticalLaneMonitoringTe
mperature
brcdIp.1.1.3.3.10.1.1
Syntax: DisplayString

Read-only

This object holds the value of the transmitter laser diode
temperature for the lane in the interface. Indicates the health of
the transmitter.
The format is xxx.yyyy C (Celcius), followed by whether the
measured value is normal, high/low alarm, or high/low warning.

snIfOpticalLaneMonitoringTx
Power
brcdIp.1.1.3.3.10.1.1
Syntax: DisplayString

Read-only

This object holds the value of the transmitter optical signal power
for the lane in the interface, measured in dBm, followed by
whether this is a this is a normal value, or high or low warning or
alarm.

Advertising