Snposinfospeed, Snposinfoadminstatus, Snposinfolinkstatus – Brocade Unified IP MIB Reference (Supporting FastIron Release 07.5.00) User Manual

Page 282: Snposinfoclock, Snposinfoloopback, Snposinfoscrambleatm, Snposinfoframing, Snposinfocrc

Advertising
background image

254

Unified IP MIB Reference

53-1002549-02

Packet port information table

snPOSInfoSpeed
brcdIp.1.2.14.1.1.1.5
Syntax: Integer

Read-write

The bandwidth of the interface, which can be one of the following:

s155000(1) bps

s622000(2) bps

other(3)

s2488000(4) bps

snPOSInfoAdminStatus
brcdIp.1.2.14.1.1.1.6
Syntax: Integer

Read-write

The desired state of the interface, which can be one of the
following:

up(1) – The port is ready to pass packets.

down(2) – The port is not ready to pass packets.

testing(3) – The port is in test mode. No packets can be
passed.

snPOSInfoLinkStatus
brcdIp.1.2.14.1.1.1.7
Syntax: Integer

Read-only

The current operational state of the link, which can be one of the
following:

up(1) – The port is ready to pass packets.

down(2) – The port is not ready to pass packets.

testing(3) – The port is in test mode. No packets can be
passed.

snPOSInfoClock
brcdIp.1.2.14.1.1.1.8
Syntax: Integer

Read-write

The clock source, which can be one of the following:

internal(1) – The interface is using the clock on the POS
module.

line(2) – The interface is using the clock source supplied on
the network.

Default: internal(1)

snPOSInfoLoopBack
brcdIp.1.2.14.1.1.1.9
Syntax: Integer

Read-write

The loopback state of the interface. The loopback state can be one
of the following:

line(1) – The loopback path consists of both this POS interface
and the POS interface at the remote end of the link. Use this
mode to check the POS interface along the link.

internal(2) – The loopback path consists only of the POS
circuitry on this interface. Use this mode to check the POS
circuitry.

none(3) – The interface is not operating in loopback mode.

snPOSInfoScrambleATM
brcdIp.1.2.14.1.1.1.10
Syntax: Integer

Read-write

The state of the ATM scramble mode, which can be one of the
following:

disabled(0) – Scrambling is disabled.

enabled(1) – Scrambling of the Synchronous Payload Envelope
(SPE) is enabled. Data in the SONET packet is scrambled for
security.

Default: disabled(0)

snPOSInfoFraming
brcdIp.1.2.14.1.1.1.11
Syntax: Integer

Read-write

The frame type used on the interface. The frame type can be one of
the following:

sonet(1) – Synchronous Optical Network.

sdh(2) – Synchronous Digital Hierarchy.

Default: sonet(1)

snPOSInfoCRC
brcdIp.1.2.14.1.1.1.12
Syntax: Integer

Read-write

The length of the CRC field in packets transmitted on the interface.
The length can be one of the following:

crc32bits(1) – The field is 8 bits long.

crc16bits(2) – The field is 16 bits long.

Default: crc32bits(1)

Name, OID, and syntax

Access

Description

Advertising