Sntrapopticalmonitoringwarning, Sntrapopticalmonitoringalarm, Sntrapopticalmonitoringerror – Brocade Unified IP MIB Reference (Supporting FastIron Release 07.5.00) User Manual
Page 716
688
Unified IP MIB Reference
53-1002549-02
Proprietary traps
Trap name and number
Varbinds
Severity
Description and trap message
snTrapOpticalMonitoringWarning
brcdIp.0.1003
NOTE: This trap is supported on
the Brocade NetIron MLX,
Brocade MLXe, Brocade
NetIron XMR, Brocade
NetIron CES, and Brocade
NetIron CER series devices.
snAgGblTrapMessage Warnin
g
A warning occurred during optical
monitoring.
Sample trap message:
Latched high Temperature
alarm, port <slot>/<port>
snTrapOpticalMonitoringAlarm
brcdIp.0.1004
NOTE: This trap is supported on
the Brocade NetIron MLX,
Brocade MLXe, Brocade
NetIron XMR, Brocade
NetIron CES, and Brocade
NetIron CER series devices.
snAgGblTrapMessage Alerts
An alarm occurred during optical
monitoring due to a low temperature in
the device.
Sample trap message:
Latched low Temperature
alarm, port <slot>/<port>
snTrapOpticalMonitoringError
brcdIp.0.1005
NOTE: This trap is supported on
the Brocade NetIron MLX,
Brocade MLXe, Brocade
NetIron XMR, Brocade
NetIron CES, and Brocade
NetIron CER series devices.
snAgGblTrapMessage Informa
tional
An error occurred during optical
monitoring.
Samples trap message:
OPTICAL MONITORING:
sys_create_timer failed, slot
<n>, port mask <portmask>
OPTICAL MONITORING:
sys_set_timer failed, slot
<n>, port mask <portmask>
OPTICAL MONITORING:
THRESHOLDS READ FAILED, port
<slot>/<port>
OPTICAL MONITORING: AUX AD
TYPE READ FAILED, port
<slot>/<port>"
OPTICAL MONITORING: INT
UNMASK ALL WRITE FAILED, port
<slot>/<port>
OPTICAL MONITORING: INT MASK
WRITE FAILED, port
<slot>/<port>
OPTICAL MONITORING:: XFP INT
MASK WRITE FAILED, port
<slot>/<port>
OPTICAL MONITORING: port
<slot>/<port>:
sys_create_timer failed
OPTICAL MONITORING: port
<slot>/<port>:
sys_create_timer2 failed
OPTICAL MONITORING: port
<slot>/<port>: sys_set_timer
failed