General traps for the brocade netiron devices, Sntrapifindexassignmentc hanged, Sntrapmodulestatuschang e – Brocade Unified IP MIB Reference (Supporting FastIron Release 07.5.00) User Manual

Page 748

Advertising
background image

720

Unified IP MIB Reference

53-1002549-02

General traps for the Brocade NetIron devices

1. Configure a RMON alarm with an ID of 1 that checks for snAgGblCpuUtil1MinAvg every 300

seconds. In every sample, check if the CPU utilization fall exceeds 50 percent. If it does, send
an event(id 1) with Tom. The event trigger is re-armed, when the falling-threshold value falls
below 45 percent.

Brocade(config)# rmon alarm 1 snAgGblCpuUtil1MinAvg.0 300 absolute

rising-threshold 50 1 falling-threshold 45 65535 owner Tom

2. Configure a RMON event with an ID of 1, which sends a SNMP trap that contains the

community string "public", some description, and owner Tom whenever CPU utilization exceeds
50 percent.

Brocade(config)# rmon event 1 description "CPU Utilization exceeds 50%" trap

public owner Tom

General traps for the Brocade NetIron devices

The following table presents the general traps for the Brocade NetIron MLX, Brocade MLXe,
Brocade NetIron XMR, Brocade NetIron CES, and Brocade NetIron CER series devices.

Trap name and number

Varbinds

Severity

Description and trap message

snTrapIfIndexAssignmentC
hanged
brcdIp.0.172

snAgGblTrapMessage

Informational The SNMP trap is generated when the

interface index (ifIndex) assignment for a
physical interface is changed.
Sample trap message:
System: IfIndex assignment was

changed

snTrapModuleStatusChang
e
brcdIp.0.176

snChasUnitIndex,
snAgentBrdIndex,
snAgentBrdModuleSt
atus, and
snAgGblTrapMessage

Notification

The operational state of a module is
changed. The management entity receiving
the notification can identify the module and
the event by referencing snChasUnitIndex,
snAgentBrdIndex, and
snAgentBrdModuleStatus.
If the module is down, the
snAgGblTrapMessage varbind contains a
text string that describes the cause.
If the module is up, nothing is displayed for
snAgGblTrapMessage.
Sample trap message:
For module up: System: Module up in
slot <slot-number>

For module down: System: Module
down in slot <slot-number>,

reason <reason. Error Code

<error-code>
For standby MP up: System: Standby
Management Module was ready
For standby MP down: System: Standby
Management Module was down,

reason <reason>. Error Code

<error-code>