Rfc 2863: the interfaces group mib, Ifindex, Physical port – Brocade Unified IP MIB Reference (Supporting FastIron Release 07.5.00) User Manual

Page 46: Mgmt port, Virtual port, Loopback port, Ip tunnels, Mpls tunnels, Trunk

Advertising
background image

18

Unified IP MIB Reference

53-1002549-02

RFC 2863: The Interfaces Group MIB

RFC 2863: The Interfaces Group MIB

RFC 2863 is supported only on the Brocade NetIron XMR, Brocade NetIron MLX, Brocade MLXe,
Brocade NetIron CES, and Brocade NetIron CER series devices.

ifIndex

On the Brocade NetIron XMR, Brocade NetIron MLX, and Brocade MLXe devices, there can be 20,
40, 48, or 64 ifIndexes per module. (Refer to the Configuring SNMP ifIndex section of the
Configuring Basic Parameters chapter in the NetIron Configuration Guide for details.) The default
is 20. Issue the snmp-server max-ifindex-per-module 40 CLI command to change the ifIndex to 40
(for example, for backward-compatibility).

On the Brocade NetIron XMR, Brocade NetIron MLX, and Brocade MLXe devices, every trunk group
will appear as a row within the ifTable and ifXTable. The ifIndex range involves all the physical ports,
virtual ports, loopback ports, multicast tunnels, GRE tunnels, MPLS tunnels, and Trunks in that
order.

Use the Get operations on snInterfaceLookupIfIndex (indexed by ifIndex) to get InterfaceId (in a
simple OID form).

Table 2

details the XMR or MLX index ranges and they are subject to change from one release to

the next.

TABLE 2

XMR or MLX index ranges

4-slot

8-slot

16-slot

32-slot

Allocation

Physical port

1-192

1-384

1-768

1-1536

20 per slot
(NetIron release
3.7 and later)
40 per slot
(NetIron releases
prior to 3.7)
48 per slot
(NetIron releases
prior to 5.2)

Mgmt port

2

2

2

2

1 active, 1
standby

Virtual port

255 default, 40
minimum, 4096
maximum

255 default, 40
minimum, 4096
maximum

255 default, 40
minimum, 4096
maximum

255 default,
40 minimum,
4096
maximum

Loopback port

64 default

64 default

64 default

64 default

IP tunnels

8192

8192

8192

8192

MPLS tunnels

16384

16384

16384

16384

Trunk

128 default, 128
minimum, 256
maximum

128 default, 128
minimum, 256
maximum

128 default, 128
minimum, 256
maximum

128 default,
128
minimum,
256 maximum