Snpimprunetime, Snpimgraftretransmittime, Snpiminactivitytime – Brocade Unified IP MIB Reference (Supporting FastIron Release 07.5.00) User Manual

Page 588: Pim virtual interface table, Snpimvinterfacetable, Snpimvinterfacevifindex

Advertising
background image

560

Unified IP MIB Reference

53-1002549-02

PIM virtual interface table

PIM virtual interface table

The PIM virtual interface table lists the PIM virtual interfaces on a Layer 3 Switch.

NOTE

The PIM virtual interface table is not supported on the Brocade NetIron MLX, Brocade MLXe,
Brocade NetIron XMR, Brocade NetIron CES, and Brocade NetIron CER series devices.

snPimPruneTime
brcdIp.1.2.9.1.4
Syntax: Integer

Read-write

Specifies the number of seconds that a PIM Layer 3
Switch will maintain a prune state for a forwarding entry.
The first multicast that the Layer 3 Switch receives from
an interface is forwarded to all other PIM interfaces on the
Layer 3 Switch. If there is no presence of groups on that
interface, the leaf node sends a prune message upstream
and stores a prune state. This prune state travels up the
tree and installs a prune state.
A prune state is maintained until the prune timer expires
or a graft message is received for the forwarding entry.
Valid values: 10 – 3600 seconds
Default: 60 seconds

snPimGraftRetransmitTime
brcdIp.1.2.9.1.5
Syntax: Integer

Read-write

Specifies the number of seconds between the
transmission of graft messages.
A graft message is sent by a Layer 3 Switch to cancel a
prune state. When a Layer 3 Switch receives a graft
message, the Layer 3 Switch responds with a Graft ACK
(acknowledge) message. If this Graft ACK message is lost,
the Layer 3 Switch that sent the graft message will resend
it.
For NetIron platforms:

Valid values: 2 – 3600 seconds

Default: 180 seconds

For FastIron platforms:

Valid values: 2 – 10 seconds

Default: 3 seconds

snPimInactivityTime
brcdIp.1.2.9.1.6
Syntax: Integer

Read-write

Defines how long a forwarding entry can remain unused
before the Layer 3 Switch deletes it. The Layer 3 Switch
deletes a forwarding entry if the entry is not used to send
multicast packets.
This object is used only to keep the forwarding entries for
the active sessions.
Valid values: 10 – 3600 seconds
Default: 180 seconds

Name, OID, and syntax

Access

Description

Name, OID, and syntax

Access

Description

snPimVInterfaceTable
brcdIp.1.2.9.1.7

None

The PIM virtual interface table.

snPimVInterfaceVifIndex
brcdIp.1.2.9.1.7.1.1
Syntax: Integer

Read-only

The ifIndex value of this PIM virtual interface. There can be
up to 48 entries.
Valid values: 1 - 48

Advertising