RTLS config commands

21

controller

RTLS config commands

Configures the controller’s geographical location parameters

Supported in the following platforms:

Mobility RFS4000 Controller

Mobility RFS6000 Controller

Mobility RFS7000 Controller

Syntax

controller

[coordinates|geo-coordinates]

controller coordinates

x <0-65535> y <0-65535> z <0-65535>

controller geo-coordinates

longitude <-180.00-80.00>

latitude <-90.00 - 90.00>

Parameters

Example

RFController(config-rtls)#controller coordinates x 121 y 121 z 135

RFController(config-rtls)#

RFController(config-rtls)#controller geo-coordinates longitude 120 latitude 70

RFController(config-rtls)#

coordinates x <0-65535> y
<0-65535> z <0-65535>

Configures controller coordinates within the site

x <0-65535> – Configures X coordinate

y <0-65535> – Configures Y coordinate

z <0-65535> – Configures Z coordinate

longitude <-180.00-80.00>
latitude
<-90.00 - 90.00>

Configures controller geographic coordinates

longitude <-180.00-180.00> – Configures longitude in
degrees

latitude <-90.00-90.00> – Configures latitude in degrees