Status register (word offset 0x01), Status register (word offset 0x01) -22 – Altera Triple Speed Ethernet MegaCore Function User Manual

Page 105

Advertising
background image

Description

R/W

Name

Bit(s)

Self-clearing reset bit. Set this bit to 1 to generate a
synchronous reset pulse which resets all the PCS function
state machines, comma detection function, and 8b/10b
encoder and decoder. For normal operation, set this bit to
0 (asynchronous reset value).

RW

RESET

15

Status Register (Word Offset 0x01)

Table 6-14: Status Register Bit Descriptions

Description

R/W

Name

Bit

A value of 1 indicates that the PCS function
supports extended registers.

RO

EXTENDED_CAPABILITY

0

Unused. Always set to 0.

JABBER_DETECT

1

A value of 1 indicates that a valid link is established.
A value of 0 indicates an invalid link.

If the link synchronization is lost, a 0 is latched.

RO

LINK_STATUS

2

A value of 1 indicates that the PCS function
supports auto-negotiation.

RO

AUTO_NEGOTIATION_

ABILITY

3

Unused. Always set to 0.

REMOTE_FAULT

4

A value of 1 indicates the following status:

• The auto-negotiation process is completed.
• The auto-negotiation control registers are valid.

RO

AUTO_NEGOTIATION_

COMPLETE

5

Unused. Always set to 0.

MF_PREAMBLE_SUPPRESSION

6

A value of 1 indicates that the PCS is able to
transmit from MII/GMII regardless of whether the
PCS has established a valid link.

RO

UNIDIRECTIONAL_ABILITY

7

Unused. Always set to 0.

EXTENDED_STATUS

8

Configuration Register Space

Altera Corporation

Send Feedback

UG-01008

Status Register (Word Offset 0x01)

6-22

2014.06.30

Advertising