(1)

Clocks

MAC and PCS with PMA

MAC and PCS

MAC Only

Notes to

Table 8-1

:

1. Yes indicates that the clock is visible at the top-level design. No indicates that the clock is not visible at

the top-level design. — indicates that the clock is not applicable for the given configuration.

2. Applies to GX transceiver.

MAC and PCS With GX Transceivers

In configurations that contain the MAC, PCS, and GX transceivers, you have the following options in
optimizing clock resources:

• Utilize the same reset signal for all MAC instances if you do not require a separate reset for each instance.
• Utilize the same reference clock for all PMA quads
• Utilize the same clock source to drive the reference clock, FIFO transmit and receive clocks, and system

clocks, if these clocks run at the same frequency.

The Quartus II software automatically optimizes the TBI transmit clocks. Only one clock source drives the
TBI transmit clocks from each PMA quad.

The calibration clock (

gxb_cal_blk_clk

) calibrates the termination resistors in all transceiver channels in

a device. As there is only one calibration circuit in each device, one clock source suffices.

If you do not constrain the PLL inputs and outputs in your design, add

derive_pll_clocks

in the

timing constraint file to ensure that the TimeQuest timing analyzer automatically creates derived
clocks for the PLL outputs.

Note:

Design Considerations

Altera Corporation

Send Feedback

UG-01008

MAC and PCS With GX Transceivers

8-2

2014.06.30