Triple-Speed Ethernet System with SGMII

Figure 6-3: Triple-Speed Ethernet System with SGMII with Register Initialization Recommendation

10/100/1000 Mbps MAC

External PHY

MAC

Register

Space

MDIO Space 0

MDIO Space 1

MDIO

Host

PHY

Register

Space

MDIO

Slave

Avalon ST TX

Avalon ST RX

Avalon MM

Copper/Fiber
Interface

SGMII Interface (1.25 Gbps)

MDIO

1000BASE-X/

SGMII PCS

PCS

Register

Space

Use the following recommended initialization sequences for the example in

Figure 6–4

.

1. External PHY Initialization using MDIO

Refer to step 1 in

Triple-Speed Ethernet System with MII/GMII or RGMII

on page 6-28.

2. PCS Configuration Register Initialization

a. Set Auto Negotiation Link Timer

//Set Link timer to 1.6ms for SGMII

link_timer (address offset 0x12) = 0x0D40

Link_timer (address offset 0x13) = 0x03

b. Configure SGMII

//Enable SGMII Interface and Enable SGMII Auto Negotiation

//SGMII_ENA = 1, USE_SGMII_AN = 1

if_mode = 0x0003

c. Enable Auto Negotiation

//Enable Auto Negotiation

//AUTO_NEGOTIATION_ENA = 1, Bit 6,8,13 can be ignore

PCS Control Register = 0x1140

d. PCS Reset

//PCS Software reset is recommended where there any configuration changed

//RESET = 1

Configuration Register Space