Special internal relays, Caution – IDEC MicroSmart User Manual

Page 171

Advertising
background image

6: A

LLOCATION

N

UMBERS

« FC4A M

ICRO

S

MART

U

SER

S

M

ANUAL

»

6-7

Special Internal Relays

Special internal relays M8000 through M8077 are read/write internal relays used for controlling the CPU operation and
communication. Special internal relays M8080 through M8157 are read-only internal relays primarily used for indicating
the CPU statuses. All special internal relays cannot be used as destinations of advanced instructions.

Internal relays M300 through M315 are used to read input operand statuses of the IOREF (I/O refresh) instruction.

Special Internal Relay Allocation Numbers (Read/Write)

• Do not change the status of reserved special internal relays, otherwise the

MicroSmart

may not

operate correctly.

Allocation

Number

Description

CPU Stopped

Power OFF

M8000

Star t Control

Maintained

Maintained

M8001

1-sec Clock Reset

Cleared

Cleared

M8002

All Outputs OFF

Cleared

Cleared

M8003

Carr y (Cy) or Borrow (Bw)

Cleared

Cleared

M8004

User Program Execution Error

Cleared

Cleared

M8005

Data Link Communication Error

Maintained

Cleared

M8006

Data Link Communication Prohibit Flag (Master Station)

Maintained

Maintained

M8007

Data Link Communication Initialize Flag (Master Station)
Data Link Communication Stop Flag (Slave Station)

Cleared

Cleared

M8010

Status LED

Operating

Cleared

M8011

HMI Write Prohibit Flag

Maintained

Cleared

M8012

HMI Operation Prohibit Flag

Maintained

Cleared

M8013

Calendar/Clock Data Write/Adjust Error Flag

Operating

Cleared

M8014

Calendar/Clock Data Read Error Flag

Operating

Cleared

M8015

Calendar/Clock Data Read Prohibit Flag

Maintained

Cleared

M8016

Calendar Data Write Flag

Operating

Cleared

M8017

Clock Data Write Flag

Operating

Cleared

M8020

Calendar/Clock Data Write Flag

Operating

Cleared

M8021

Clock Data Adjust Flag

Operating

Cleared

M8022

User Communication Receive Instruction Cancel Flag (Por t 1)

Cleared

Cleared

M8023

User Communication Receive Instruction Cancel Flag (Por t 2)

Cleared

Cleared

M8024

BMOV/WSFT Executing Flag

Maintained

Maintained

M8025

Maintain Outputs While CPU Stopped

Maintained

Cleared

M8026

Expansion Data Register Data Writing Flag (Preset Range 1)

Operating

Maintained

M8027

Expansion Data Register Data Writing Flag (Preset Range 2)

Operating

Maintained

M8030

High-speed Counter 1 (I0-I2) Comparison Output Reset

Cleared

Cleared

M8031

High-speed Counter 1 (I0-I2) Gate Input

Maintained

Cleared

M8032

High-speed Counter 1 (I0-I2) Reset Input

Maintained

Cleared

M8033

— Reser ved —

M8034

High-speed Counter 2 (I3) Comparison Output Reset

Cleared

Cleared

M8035

High-speed Counter 2 (I3) Gate Input

Maintained

Cleared

M8036

High-speed Counter 2 (I3) Reset Input

Maintained

Cleared

M8037

— Reser ved —

M8040

High-speed Counter 3 (I4) Comparison Output Reset

Cleared

Cleared

M8041

High-speed Counter 3 (I4) Gate Input

Maintained

Cleared

M8042

High-speed Counter 3 (I4) Reset Input

Maintained

Cleared

M8043

— Reser ved —

M8044

High-speed Counter 4 (I5-I7) Comparison Output Reset

Cleared

Cleared

Caution