Sample program - user communication txd, Sample program – user communication txd -32, Sample program – user communication txd – IDEC MicroSmart User Manual

Page 310

Advertising
background image

17: U

SER

C

OMMUNICATION

I

NSTRUCTIONS

17-32

« FC4A M

ICRO

S

MART

U

SER

S

M

ANUAL

»

Sample Program – User Communication TXD

This example demonstrates a program to send data to a printer using the user communication TXD2 (transmit) instruction,
with the optional RS232C communication adapter installed on the port 2 connector of the 24-I/O type CPU module.

System Setup

The name of BUSY terminal differs depending on printers, such as DTR. The function of this terminal is to send a signal
to remote equipment whether the printer is ready to print data or not. Since the operation of this signal may differ depend-
ing on printers, confirm the operation before connecting the cable.

Description of Operation

The data of counter C2 and data register D30 are printed every minute. A printout
example is shown on the right.

Programming Special Data Register

Special data register D8105 is used to monitor the BUSY signal and to control the
transmission of print data.

The

MicroSmart

monitors the DSR signal to prevent the receive buffer of the printer from overflowing. For the DSR sig-

nal, see page 17-30.

Special DR

Value

Description

D8105

3

While DSR is on (not busy), the CPU sends data.
While DSR is off (busy), the CPU stops data transmission.
If the off duration exceeds a limit (approx. 5 sec), a trans-
mission busy timeout error will occur, and the remaining
data is not sent. The transmit status data register stores
an error code. See pages 17-11 and 17-27.

To RS232C Por t

D-sub 9-pin Connector Pinouts

Pin

Description

1

NC

No Connection

2

NC

No Connection

3

DATA

Receive Data

4

NC

No Connection

5

GND

Ground

6

NC

No Connection

7

NC

No Connection

8

BUSY Busy Signal

9

NC

No Connection

Printer

Mini DIN Connector Pinouts

Description

Color

Pin

Shield

Cover

NC

No Connection

Black

1

NC

No Connection

Yellow

2

TXD

Transmit Data

Blue

3

NC

No Connection

Green

4

DSR

Data Set Ready

Brown

5

NC

No Connection

Gray

6

SG

Signal Ground

Red

7

NC

No Connection

White

8

User Communication Cable 1C
FC2A-KP1C
2.4m (7.87 ft.) long

Attach a proper connector to the open
end of the cable referring to the cable
connector pinouts shown below.

Cable Connection and Pinouts

To Por t 2 (RS232C)

RS232C Communication Adapter
FC4A-PC1

Caution

• Do not connect any wiring to the NC (no connection) pins; otherwise, the

MicroSmart

and the

printer may not work correctly and may be damaged.

--- PRINT TEST ---

11H 00M

CNT2...0050
D030...3854

--- PRINT TEST ---

11H 01M

CNT2...0110
D030...2124

Printout Example