AT and

are appended at the beginning and end of the initialization string automatically by the system program and are

not stored in data registers.

Depending on your modem and telephone line, the initialization string may have to be modified. Consult the manual for
your modem.

Changes can be made by entering required values to data registers D8145-D8169. Store two characters in one data regis-
ter; the first character at the upper byte and the second character at the lower byte in the data register. AT and

need not

be stored in data registers. Use the MOV (move) instructions on

WindLDR

to set the initialization string characters and

ASCII value 0Dh for

at the end. Program the MOV instructions to replace the default values in D8145-D8169 stored in

the first scan and execute the MOV instructions in a subsequent scan. For essential commands which must be included in
the initialization string, see page 27-8. After the new values are stored, turn on M8050 to send the new initialization string
to the modem.

When the initialization string has been sent successfully, internal relay M8060 is turned on. If the initialization string fails,
internal relay M8070 is turned on. When the subsequent commands of ATZ and dialing are also completed successfully,
M8061 and M8062 will also be turned on.

The default initialization string or the modified initialization string stored in D8145-D8169 is also used for the initializa-
tion in the answer mode.

ATZ (Resetting the Modem) in Originate Mode

The default initialization string specifies to be stored in the non-volatile memory of the modem, using the &W command.
The initialization string is restored when the modem is powered up or when the ATZ command is issued. The

MicroSmart

sends the ATZ command to the modem, following the initialization string when M8050 is turned on. The ATZ command
can also be issued separately by turning M8051 on, followed by the dial command to be executed automatically.

ATZ Command:

ATZ

When the ATZ command has been completed successfully, internal relay M8061 is turned on. If the ATZ command fails,
internal relay M8071 is turned on. When the subsequent dialing is also completed successfully, M8062 will also be turned
on.

If the initialization string has been stored in the non-volatile memory of the modem, M8050 may be skipped. Start with
M8051 to send the ATZ command.

Dialing the Telephone Number

Data registers D8170-D8199 are allocated to the telephone number. Before turning on one of the start internal relays
M8050-M8052 for the originate mode, store the telephone number in data registers starting with D8170. One data register
stores two characters: the first character at the upper byte and the second character at the lower byte in the data register.
Since 30 data registers are allocated to the telephone number, up to 60 characters can be stored, as many as the modem
capacity allows. Use the MOV (move) instructions on

WindLDR

to set the telephone number and execute the MOV instruc-

tions before turning on start internal relays M8050-M8052.

Example of Dial Command:

ATD1234

ATD and

are appended at the beginning and end of the dial command automatically by the system program and need

not be stored in data registers. To program the telephone number of the example above, store the telephone number and
ASCII value 0Dh for

to data registers starting with D8170. It is also possible to store character T for touch-tone phone

or P for pulse or rotary phone.

LF

0D00

8161

Q0

8146

V1

8147

&D

8148

2&

8149

C1

8150

\V

8151

0X

8152

4&

8153

K3

8154

\A

8155

0\

8156

N5

8157

S0

8158

=2

8159

&W

8160

E0

8145

AT

DR

LF

LF

CR

CR LF

CR LF

LF

CR

3132h

D8170

3334h

D8171

0D00h

D8172

31h = “1”

32h = “2”

33h = “3”

34h = “4”

0Dh =

All characters subsequent to

CR

are ignored.

CR