IDEC MicroSmart User Manual

Page 25

Advertising
background image

2: M

ODULE

S

PECIFICATIONS

« FC4A M

ICRO

S

MART

U

SER

S

M

ANUAL

»

2-5

Communication Function

* Recommended cable for RS485: Twisted-pair shielded cable with a minimum core wire of 0.3 mm

2

.

Conductor resistance 85

Ω/km maximum, shield resistance 20 Ω/km maximum.

Built-in Functions

Memory Cartridge (Option)

Clock Cartridge (Option)

Communication Port

Port 1 (RS232C)

Port 2 (RS232C)

Communication Adapter

Port 2 (RS485)

Communication Adapter

Standards

EIA RS232C

EIA RS232C

EIA RS485

Maximum Baud Rate

19,200 bps

19,200 bps

Computer link: 19,200 bps
Data link:

38,400 bps

Maintenance Communication
(Computer Link)

Possible

Possible

Possible

User Communication

Possible

Possible

Not possible

Modem Communication

Not possible

Possible

Not possible

Data Link Communication

Not possible

Not possible

Possible

Quantity of Slave Stations

31

Maximum Cable Length

Special cable

Special cable

200m *

Isolation between Internal Circuit
and Communication Port

Not isolated

Not isolated

Not isolated

High-speed Counter

Maximum Counting Frequency
and High-speed Counter Points

Total 4 points
Single/two-phase selectable: 20 kHz (1 point)
Single-phase:

5 kHz (3 points)

Counting Range

0 to 65535 (16 bits)

Operation Mode

Rotar y encoder mode and adding counter mode

Sensor Power Supply
(AC power type only)

Output Voltage/Current

24V DC (+10% to –15%), 250 mA

Overload Detection

Not available

Isolation

Isolated from the internal circuit

Analog Potentiometer

Quantity

1 point (10- and 16-I/O type CPU)
2 points (24-I/O type CPU)

Data Range

0 to 255

Memory Type

EEPROM

Accessible Memory Capacity

32 KB

Hardware for Storing Data

CPU module

Software for Storing Data

WindLDR

Quantity of Stored Programs

One user program can be stored on one memor y car tridge.

Program Execution Priority

When a memor y car tridge is installed, the user program on the memor y car tridge is
executed.

Accuracy

±30 sec/month (typical) at 25°C

Backup Duration

Approx. 30 days (typical) at 25°C after backup batter y fully charged

Battery

Lithium secondar y batter y

Charging Time

Approx. 10 hours for charging from 0% to 90% of full charge

Battery Life

Approx. 100 recharge cycles after discharging down to 10% of full charge

Replaceability

Not possible to replace batter y

Advertising