IDEC MicroSmart User Manual

Page 203

Advertising
background image

7: B

ASIC

I

NSTRUCTIONS

« FC4A M

ICRO

S

MART

U

SER

S

M

ANUAL

»

7-19

Forward Shift Register (SFR), continued

Setting and Resetting Shift Register Bits

Reset Input I0

ON

OFF

Pulse Input I1

ON

OFF

Data Input I2

ON

OFF

Timing Chart

R1/Q1

ON

OFF

One scan or more is required

R0/Q0

ON

OFF

R3/Q3

ON

OFF

R2/Q2

ON

OFF

Ladder Diagram

I0

I1

SFR

R0

4

I2

Reset

Pulse

Data

R0

R1

R2

R3

Instruction

Data

LOD
LOD
LOD
SFR

LOD
OUT
LOD
OUT
LOD
OUT
LOD
OUT

I0
I1
I2
R0
4
R0
Q0
R1
Q1
R2
Q2
R3
Q3

Program List

Q0

Q1

Q2

Q3

• The last bit status output can be programmed directly after

the SFR instruction. In this example, the status of bit R3 is
read to output Q3.

• Each bit can be loaded using the LOD R# instruction.

Instruction

Data

LOD
LOD
LOD
SFR

OUT
LOD
OUT
LOD
OUT

I1
I2
I3
R0
4
Q3
R0
Q0
R1
Q1

Program List

Ladder Diagram

I1

I2

SFR

R0

4

I3

Reset

Pulse

Data

R0

R1

Q0

Q1

Q3

I1

I0

• Any shift register bit can be turned on using the SET instruction.
• Any shift register bit can be turned off using the RST instruction.
• The SET or RST instruction is actuated by any input condition.

R0

S

R3

R