17-31

D8106 = 1:

Whether the

MicroSmart

is running or stopped, DTR remains off.

D8106 = 2:

While the

MicroSmart

can receive data, DTR is turned on. While the

MicroSmart

can not receive

data, DTR remains off. Use this option when flow control of receive data is required.

D8106 = 3 or more:

Same as D8106 = 0.

MicroSmar t

DTR signal

ON

OFF

Stopped

Running

Stopped

DTR signal

ON

OFF

Possible

Impossible

Impossible

Receive