SwitchNet Data I/O Port

SwitchNet control units can be used as slaves in the AS-Interface network and are available in ø16mm L6 series and
ø22mm HW series. Input signals to the

MicroSmart

AS-Interface master module are read to internal relays allocated to

each input point designated by a slave number and a DI number. Similarly, output signals from the

MicroSmart

AS-Inter-

face master module are written to internal relays allocated to each output point designated by a slave number and a DO
number. When programming a ladder diagram for the

MicroSmart

, use internal relays allocated to input signals and output

signals of SwitchNet control units.

L6 series and HW series SwitchNet control units have slightly different digital I/O data allocations.

L6 Series Digital I/O Data Allocation

Input data is sent from slaves to the AS-Interface master. Output data is sent from the AS-Interface master to slaves.

Notes:

SwitchNet L6 Series

Slave Unit

Used I/O

Input Data

(slave send data)

Output Data

(slave receive data)

DI3

DI2

DI1

DI0

DO3

DO2

DO1

DO0

Pushbutton

1 in

0

X1

1

1

*

Pilot light

1 out

0

0

1

1

*

X1

Illuminated pushbutton

1 in/1 out

0

X1

1

1

*

X1

Selector, Key selector, Lever: 2-position

1 in

0

X2

1

1

*

Selector, Key selector, Lever: 3-position

2 in

X3

X3

1

1

*

Illuminated selector: 2-position

1 in/1 out

0

X2

1

1

*

X1

Illuminated selector: 3-position

2 in/1 out

X3

X3

1

1

*

X1

1.

∗ The AS-Interface master uses bit DO3 for addressing A/B
slaves.

2.

In the above table, bits marked with X1, X2, and X3 are used
for SwitchNet I/O data.

3. X1: When pushbutton is pressed, input data is 1 (on). When

not pressed, input data is 0 (off). When output data is 1 (on),
LED is on. When output data is 0 (off), LED is off.

4. X2: The input data from 2-position selector, key selector, and

illuminated selector switches and 2-position lever switches
depend on the operator position as shown below.

5.

X3: The input data from 3-position selector, key selector, and
illuminated selector switches and 3-position lever switches
depend on the operator position as shown below.

6.

Unused input bits DI3 and DI2 are 0 (off), and unused input
bits DI1 and DI0 are 1 (on). Slaves ignore unused output data
(—) sent from the master.

2-position Operator

Operator Position

Left/Down

Right/Up

DI2

0

1

Selector

Left

Right

Up

Down

Lever

3-position Operator

Operator Position

Left/Down

Center

Right/Up

DI3

0

0

1

DI2

1

0

0

Selector

Left

Right

Center

Up

Center

Down

Lever

Write_Parameter Command

Write_Parameter Settings

0

0

A4

A3

A2

A1

A0

1

Sel

P3

P2

P1

P0

PB

1

LED

Brightness

Settings

Remarks

Output

Selection

Control Data

P2

P1

P0

100%

1: DO0
0: DO1

1

1

Default

50%

0

1

25%

1

0

12.5%

0

0